
Approved For Omicron
All test sold on rapidproof.com.au are verified to detect Omicron under as per the ARTG website. Negative test results do not exclude infection with SARS-CoV-2 (COVID-19); and positive test results or symptomatic persons require immediate confirmatory testing with a polymerase chain reaction (PCR) test;
Stay safe, avoid the lines and order now.
All products on RapidProof.com.au are listed on the Australian Register for Therapeutic Goods (ARTG Number 352250 & 345031. Be one of the first to secure a Rapid Antigen Self Testing kit for COVID-19
AUSTRALIA WIDE SHIPPING
Finally catch up with your family or attend work safely and reliably simply by using a 15-minute rapid TGA listed COVID-19 self-test kit from rapidproof.com.au.
The products on this website may not be suitable for you. Please read the relevant manufacturer instructions before purchase.
Testing Is In Your Hands

Quick Results
Quickly determine in 15 minutes whether you may be infected with COVID-19 from the comfort of your home.
If you test positive, a PCR test is required.

Easy to use
As the swab only has to be inserted into the lower nasal cavity, collection of the sample is relatively simple and comfortable.
All the necessary materials are included within the kit, with only 4 quick and straight forward steps required to complete the test.

Reliable Results
The test determines your infection status with a high level of accuracy and precision.
Results have been analysed across many SARS-CoV-2 variants, with no change in accuracy.
Approved for use by the Australian Government.
How To Use Rapid Antigen Kit
Featured columns

1. Take a sample
Wash your hands before performing the test.
Take the swab out of the packaging, being careful to only touch the swab by the handle.
Tilt your head back slightly. Insert the swab into one nostril. Slowly push the swab forward about 2 cm (parallel to the roof of your mouth) until you feel resistance. Do not apply any pressure.
Turn the swab 4 times (for a total of approx. 15 seconds) against the inside of the nose and then remove it from the nose.
Repeat with the same swab in the other nostril.

2. Dissolve the sample in the extraction buffer
Place the swab in a tube with extraction buffer.
Squeeze the tube at the bottom and rotate the swab gently more than 10 times.
Continue to squeeze the sides of the tube while removing the swab to force all of the liquid out of the swab.
Press the dispenser cap firmly onto the tube.

3. Apply the dissolved sample to the test cassette
Place the test strip on a flat surface.
Hold the tube vertically over the
round marked area (not the rectangular result window).
Drop exactly 4 drops on the field.
To do this, gently squeeze the tube if necessary.

4. Check the result
Set a timer and read the test result after 15-30 minutes.
If the test result is read after more than 30 minutes, the result may be incorrect.
Rapid Proof Brands
Text About Only Stocking The Best Brands TGA Listed

JusChek COVID-19 Nasal Rapid Self Test Kit 5 Pack
Rapid Antigen Self Testing kit for COVID-19 that is listed on the Australian Register for Therapeutic Goods (ARTG Number 374574).

Hough Pharma COVID Antigen Nasal Test
Be one of the first to secure a Rapid Antigen Self Testing kit for COVID-19 that is listed on the Australian Register for Therapeutic Goods (ARTG Number 345031).

Roche SARS-CoV-2 Antigen Self Test Nasal
Be one of the first to secure a Rapid Antigen Self Testing kit for COVID-19 that is listed on the Australian Register for Therapeutic Goods (ARTG Number 352250).
FAQ
About Rapid Testing Kits
Yes, ALL tests kits on our website are included in the Australian Register of Therapeutic Goods. Please refer here.
Under TGA guidelines, we are unable to provide performance details. Please refer to the documentation provided by each manufacturer. For more information on the accuracy of the rapid testing kits please see product pages of each brand.
Rapid Proof is one of Australia’s leading independent distributors of SARS-CoV-2 Antigen Self Tests.
Based in Melbourne, we are wholesale distributors of Roche Diagnostics and Hough Pharma Rapid Testing Kits. We are proud to support them in their commitment to help Australia manage and respond to the pandemic.
Our aim is to provide you with an exceptional level of service.
General Questions
Rapid Antigen tests - or lateral flow tests are used to detect antigens of the SARS-CoV-2 virus in nasal samples of individuals who are suspected of having COVID-19. This test is intended for self testing (eg. in the home or other environment).
These tests are not replacements for PCR tests. If you are concerned it is always best to conduct relevant authorities and have a PCR test.
The test can help you to quickly and easily determine whether you might be infected with SARS-CoV-2 or not. You can test yourself from the comfort of your home, without any specific training necessary.
The test has a shelf life of between 12-24 months from the manufacturing date depending on the manufacturer. The manufacturing and expiry date can be found on the back of the kit box inside the test kit.
The following items are required to perform the test and are included in each kit:
Test device (individually packed in a foil pouch with desiccant)
Tube with extraction buffer and carrier
Dispense cap
Sterile swab
The Hough Pharma kit also comes with a torch to help determine accurate results.
Roche is a swiss based company and the Roche Sars-CoVI-2 tests are manufactured SD Biosensor in South Korea.
Hough Pharma tests are manufactured by BIOHIT HealthCare (Hefei) Co Ltd (China).
How to handle the tests
Remove the swab from the packaging. Ensure that you only touch the handle of the swab and not the soft pad at the tip. Slightly tilt your head backwards and insert the swab with the soft pad at the front into your left nostril. Slowly slide the swab approx. 2 cm forward (parallel to the roof of your mouth - not upwards) until you encounter resistance. You should not apply any pressure. Then rotate the swab 4 times (for a total of approx. 15 seconds) against the lining of the nasal wall before removing it from the nostril. Repeat these steps in your right nostril using the same swab.
The test should be used at room temperature (15 - 30 °C).